Work of erection of new 100 kva dtc at taliar waddo, bella floor, ucassaim under subdiv iii(r) mapusa. <br /> Supply and erection of rcc pole 11 meters as per the drawing no. <br /> Supply and erection of rcc pole 11 meters. <br /> erection of rcc pole 9 meters. <br /> Erection of rcc pole 9 meters as per the drawing no. <br /> Supply and erection hdgi 2 pin x arm of 75 x 40 channel as per the drawing no. <br /> Supply and erection hdgi 2 pin x arm of 75 x 40 channel as per the drawing no. <br /> Supply and erection hdgi 4 pin x arm of 75 x 40 channel as per the drawing no. <br /> Supply and erection hdgi 4 pin x arm of 75 x 40 channel as per the drawing no. <br /> Supply and erection hdgi cut point of 75 x 40 x 7.3 mm channel 1.3 meters long as per the drawing no ee/iv/11 kv/x-arms as per annexure confirming to is -2633/72or the latest version thereof. <br /> Supply and erection hdgi cut point of 75 x 40 x 7.3 mm channel 1.3 meters long as per the drawing no ee/iv/11 kv/x-arms as per annexure confirming to is -2633/72or the latest version thereof. <br /> supply and erection hdgi x arm clamps for rcc pole 7.5 meters l.a as per the drawing no. <br /> supply and erection hdgi x arm clamps for rcc pole 7.5 meters l.a as per the drawing no. <br /> Supply and erection hdgi x arm clamps for rcc pole 9.00 meters l.a. as per the drawing no. <br /> Supply and erection hdgi x arm clamps for rcc pole 11.00 meters l.a as per the drawing no. <br /> Supply and erection hdgi stay clamps for rcc pole 11.00 meters l.a.as per the drawing no. <br /> Supply and erection hdgi stay clamps for rcc pole 7.5 meters l.a. as per the drawing no. <br /> Supply and erection of hdg.i. stay wire 7/10 swg conforming to is-2141/1979 grade- i, is4826-1979 and is6594-1974 or latest version thereof with tensile grade 4 and having minimum tensile strenght of 700n/mm2 conforming to is2141 or the latest version thereof. <br /> Supply and erection of hdg.i. stay wire 7/10 swg conforming to is-2141/1979 grade- i, is4826-1979 and is6594-1974 or latest version thereof with tensile grade 4 and having minimum tensile strenght of 700n/mm2 conforming to is2141 or the latest version thereof. <br /> Supply and erection of h.d.g.i. stay rod of 1200mm long and 16mm dia with an eye band of internal dia 40mm at one end andthreaded up to length of 200mm at the other end galvanised. h.d.g.i.stay plate of 450x450x8mm size with a hole drilled at the centre to suit 16mm dia gi rod galvanised.as per the drawing no. cee/e-465. <br /> Supply and erection of h.d.g.i. stay rod of 1200mm long and 16mm dia with an eye band of internal dia 40mm at one end andthreaded up to length of 200mm at the other end galvanised. h.d.g.i.stay plate of 450x450x8mm size with a hole drilled at the centre to suit 16mm dia gi rod galvanised.as per the drawing no. cee/e-465. <br /> supply and erection g.i. turn buckle with eye bolt 11 kv as per the drawing no. cee/e-466. <br /> Supply and erection of break insulators 8 kv (44kn) as per the drawing no. cee/e-425 as per annexure confirming to the is5300-1969 or the latest version thereof. <br /> Supply of g.i.nuts and bolts as per annexure confirming to the is- 2633/72 or the latest version thereof. <br /> Supply and erection 11 kv brown glazed ball and socket type disc insulators as per the drawing no. cee/e-128 conforming to is2486 pt no.1 to 4 and type 46 of is-3188/80 as ammended upto date for a minimum failing load of 45kn with minimum creepage distance of 320 mm with16mm ball and socket alternative b. <br /> Supply and erection 11 kv brown glazed ball and socket type disc insulators as per the drawing no. <br /> Supply and erection of metal parts for 11 kv disc 45 kn, 3 bolted type as per is-2486 part - iiand iii /1974 as ammended upto dateand 3 u bolted type tension/ suspension clamp. <br /> Supply and erection of metal parts for 11 kv disc 45 kn, 3 bolted type as per is-2486 part - iiand iii /1974 as ammended upto dateand 3 u bolted type tension/ suspension clamp. <br /> Supply and erection of lt brown glazed shackle insulator of size 100 mm x 115 mm conforming to fig no. 4 and type 2 fo is 1445/77 as amended upto date. <br /> supply and erection of lt brown glazed shackle insulator of size 100 mm x 115 mm conforming to fig no. 4 and type 2 fo is 1445/77 as amended upto date. <br /> Supply and erection metal parts for l.t. shackle insulators or the strap type fittings shall consists of a pair of h.d.g.i. straps, 2nos h.d.g.i. bolts with hexagonal head and nuts, 2 nos h.d.g.i. spring washers, and helically formed conductor dead-end fittings made of aluminium alloy or aluminium-clad steel conforming to the relevant is specifications as per the drawing no.ee/x/trn/drg1/2. <br /> Supply and erection metal parts for l.t shackle insulators or the strap type fittings shall consists of a pair of h.d.g.i. straps, 2nos h.d.g.i. bolts with hexagonal head and nuts, 2 nos h.d.g.i. spring washers, and helically formed conductor dead-end fittings made of aluminium alloy or aluminium-clad steel conforming to the relevant is specifications. <br /> Supply and erection l.t. brown glazed porcelain pin insulators of size 100mmx70mm conforming to type 1 fig 1 of is 1445/1977 with amendment 2 of feb 1981 (second revision) as amended upto date as per the drawing no. <br /> Supply and erection g.i. pin for l.t.pin insulators conforming to is 7935/1975 as amended upto date suitable for lt porcelain pin insulator type 1 conforming to fig 1 of is 1445/77 with amendment no 2 feb 1981, of size 100 x 70 mm. gi pin shall comprise of gi nut and spring washer and conform to fig no 2 of is 7935/1975. minimum failing load of pin shall be 3.5 kn l.t. pin insulators. <br /> Supply and erection g.i. pin for l.t.pin insulators conforming to is 7935/1975 as amended upto date suitable for lt porcelain pin insulator type 1 conforming to fig 1 of is 1445/77 with amendment no 2 feb 1981, of size 100 x 70 mm. gi pin shall comprise of gi nut and spring washer and conform to fig no 2 of is 7935/1975. minimum failing load of pin shall be 3.5 kn l.t. pin insulators. <br /> Removing and restringing of aac ant conductor, hard drawn stranded aluminium conductor and conforming to is398(pt-i/76) with ammendment no. 1,2 and 3 and of size 7/3.10mm aluminium, (nominal aluminium area 50mm). <br /> Removing and restringing of aac gnat conductor, hard drawn stranded aluminium conductor and conforming to is398(pt-i/76) with ammendment no. 1,2 and 3 and of size 7/2.21mm aluminium, (nominal aluminium area 25mm2). <br /> Supply and stringing of aac ant conductor, hard drawn stranded aluminium conductor and conforming to is398(pt-i/76) with ammendment no. 1,2 and 3 and of size 7/3.10mm aluminium, (nominal aluminium area 50mm). <br /> Supply and stringing of aac gnat conductor, hard drawn stranded aluminium conductor and conforming to is398(pt-i/76) with ammendment no. 1,2 and 3 and of size 7/2.21mm aluminium, (nominal aluminium area 25mm2). <br /> Supply and stringing of aac gnat conductor, hard drawn stranded aluminium conductor and conforming to is398(pt-i/76) with ammendment no. 1,2 and 3 and of size 7/2.21mm aluminium, (nominal aluminium area 25mm2). <br /> Supply and stringing of hard drawn stranded aluminium conductor galvanized steel reinforced and conforming to is398(pt-ii/96) with amendment no. 1 and 3 and of size 6/2.59 mm aluminium, 1/2.59 mm steel wire weasel. <br /> Supply and erection pvc insulated single core cable 50 mm2 for d.p. earthing. <br /> Supply and erection pvc insulated single core cable 50 mm2 for d.p. earthing frp fencing complete with gate as per specification for distribution transformer (size 3mx3mx2m) with concreting for frp fencing supports with plinth (0.3x0.3x0.5) cu.m. x 12 nos each ratio 136 frp fencing complete with gate as per specification for distribution transformer (size 3mx3mx2m) with concreting for frp fencing supports with plinth (0.3x0.3x0.5) cu.m. x 12 nos each ratio 136. <br /> Supply and erection 100 kva 11kv/.4kv distribution transformers level ii losses, alluminium winding, with bimetallic
Work of erection of new 100 kva dtc at taliar waddo, bella floor, ucassaim under subdiv iii(r) mapusa.
Supply and erection of rcc pole 11 meters as per the drawing no.
Supply and erection of rcc pole 11 meters.
erection of rcc pole 9 meters.
Erection of rcc pole 9
Bolts And Nuts Tenders, Bus Bar Tenders, Cable Laying Tenders, Circuit Breakers/Fuse Tenders, Conductor Tenders, Cross Arms Tenders, Distribution Board Tenders, Diversified Electrical Spares And Stores Tenders, Electrical Work Tenders, Fencing Work Tenders, G I Fittings Tenders, Hook Tenders, Insulation and Insulating Materials Tenders, Lightening Arrestor Tenders, Metal Products Tenders, Meter Tenders, Pipes / Fittings Tenders, R C C Product Tenders, R C C Work Tenders, Road Furniture Tenders, Rod Tenders, Structure Materials Tenders, Structure Work Tenders, Switches/Plug Tenders, Telecommunication Stores Tenders, Transformer Tenders, Washer Tenders, Wire And Cable Tenders