Requirement :
|
Supply of surgicals suture (drug items) - absorbable gelatin sponge ip 66, size 80(+-10) mm x 50 mm x 10 mm should be sterlized., "blood administration set / blood transfusion set , · sharp and easy piercing spike suitable for blood bags and standard blood containers, · transparent cylindrical drip chamber with filter.filter size should be 200+20 micrometer., · 150 cm long smooth kink resistant tubing, · efficient roller clamp to control and adjust the transfusion rate, · as per is 9824 (part 3)1996", "suction catheter, sterile. size fg 5 (for use in respiratory tract), · soft, kink resistant tubing, · rounded open tip with lateral eye, · colour coded universal funnel connector for safe connection to standard suction equipment, · length 50 cms (min.), · as per is0 88362014", "suction catheter, sterile. size fg 6 (for use in respiratory tract), · soft, kink resistant tubing, · rounded open tip with lateral eye, · colour coded universal funnel connector for safe connection to standard suction equipment, · as per is0 88362014", "suction catheter, sterile. size fg 8 (for use in respiratory tract), · soft, kink resistant tubing, · rounded open tip with lateral eye, · colour coded universal funnel connector for safe connection to standard suction equipment, · length 50 cm (min.), · as per is0 88362014", "suction catheter, sterile. size fg 10 (for use in respiratory tract), · soft, kink resistant tubing, · rounded open tip with lateral eye, · colour coded universal funnel connector for safe connection to standard suction equipment, · length 50 cm (min.), · as per is0 88362014", "suction catheter, sterile. size fg 12 (for use in respiratory tract), · soft, kink resistant tubing, · rounded open tip with lateral eye, · colour coded universal funnel connector for safe connection to standard suction equipment, · length 50 cm (min.), · as per is0 88362014", "suction catheter, sterile. size fg 14 (for use in respiratory tract), · soft, kink resistant tubing, · rounded open tip with lateral eye, · colour coded universal funnel connector for safe connection to standard suction equipment, · length 50 cm (min.), · as per is0 88362014", "suction catheter, sterile. size fg 16 (for use in respiratory tract), · soft, kink resistant tubing, · rounded open tip with lateral eye, · colour coded universal funnel connector for safe connection to standard suction equipment, · length 50 cm (min.), · as per is0 88362014", "suction catheter, sterile. size fg 18 (for use in respiratory tract), · soft, kink resistant tubing, · rounded open tip with lateral eye, · colour coded universal funnel connector for safe connection to standard suction equipment, · length 50 cm (min.), · as per is0 88362014", "suction catheter, sterile. size fg 20 (for use in respiratory tract), · soft, kink resistant tubing, · rounded open tip with lateral eye, · colour coded universal funnel connector for safe connection to standard suction equipment, · length 50 cm (min.), · as per is0 88362014", "suction catheter, sterile. size fg 22 (for use in respiratory tract), · soft, kink resistant tubing, · rounded open tip with lateral eye, · colour coded universal funnel connector for safe connection to standard suction equipment, · length 50 cm (min.), · as per is0 88362014", "sterile catheter, single use, for urinary drainage (foley balloon catheter), 2 way, size 8 fg, · made of silicone elastomer bonded with latex, · should have hard plastic valve, · smooth distal end with smooth eyes for atraumatic intubation, · symmetrical foley balloon, · balloon capacity 3- 5 ml, · as per is 11497, · color coding marking to identify size , · length, wall thickness and balloon capacity should be mentioned as per is 11497., · specification for b,c,d,e,f,g should be mentioned as per is 11497 for particular size", "sterile catheter, single use, for urinary drainage (foley balloon catheter), 2 way, size10 fg, · made of silicone elastomer bonded with latex, · should have hard plastic valve, · smooth distal end with smooth eyes for atraumatic intubation, · symmetrical foley balloon, · balloon capacity 3- 5 ml, · as per is 11497, · color coding marking to identify size , · length, wall thickness and balloon capacity should be mentioned as per is 11497., · specification for b,c,d,e,f,g should be mentioned as per is 11497 for particular size", "sterile catheter, single use, for urinary drainage (foley balloon catheter), 2 way, size20 fg, · made of silicone elastomer bonded with latex, · should have hard plastic valve, · smooth distal end with smooth eyes for atraumatic intubation, · symmetrical foley balloon, · balloon capacity 30 ± 1 ml, · as per is 11497 , · color coding marking to identify size , · length, wall thickness and balloon capacity should be mentioned as per is 11497., · specification for b,c,d,e,f,g should be mentioned as per is11497 for particular size", "sterile catheter, single use, for urinary drainage (foley balloon catheter), 2 way, size22 fg, · made of silicone elastomer bonded with latex, · should have hard plastic valve, · smooth distal end with smooth eyes for atraumatic intubation, · symmetrical foley balloon, · balloon capacity 30 ± 1 ml, · as per is 11497 , · color coding marking to identify size , · length, wall thickness and balloon capacity should be mentioned as per is 11497., · specification for b,c,d,e,f,g should be mentioned as per is11497 for particular size ", "sterile catheter, single use, for urinary drainage (foley balloon catheter), 2 way, size 24 fg, · made of silicone elastomer bonded with latex, · should have hard plastic valve, · smooth distal end with smooth eyes for atraumatic intubation, · symmetrical foley balloon, · balloon capacity 30 ± 1 ml, · as per is 11497 , · color coding marking to identify size , · length, wall thickness and balloon capacity should be mentioned as per is 11497., · specification for b,c,d,e,f,g should be mentioned as per is 11497 for particular size ", "infant feeding tube size10fg length 50 cm (min.), · two lateral eyes at distal end, · soft, kink resistant non-toxic pvc tubing, non irritant to delicate mucosa, · with female flexible mount with in-built closure, · radio opaque line, · sterile", "infant feeding tube size8fg, length 50 cm (min.), · two lateral eyes at distal end, · soft, kink resistant non-toxic pvc tubing, non irritant to delicate mucosa, · with female flexible mount with in-built closure, · radio opaque line, · sterile", "infant feeding tube size5fg length 50 cm (min.), · two lateral eyes at distal end, · soft, kink resistant non-toxic pvc tubing, non irritant to delicate mucosa, · with female flexible mount with in-built closure, · radio opaque line, · sterile", "sterile disposable perfusion set with airway and needle (adult use), ·for gravity feed only, · sharp and easy piercing spike with air vent, · transparent and flexible drip chamber, · 150 cm long smooth kink resistant tubing, · self sealing latex bulb which will also act as an port for extra medication, · efficient roller clamp to control and adjust the fluid rate, · 21 g needle, · as per is 12655 -4 standard", "sterile disposable perfusion set (infusion set) with airway and needle (paediatric use), · burette type measured volume chamber of 100 ml, · drop size of approx 60 drops per ml, · injection port,latexfree, for intermittent medication., · floating auto shut off valve (latex f
|